Change the capacitor tying GND to CHASSIS with one of a higher voltage rating
Definitely use something larger than 0402 and rated for 50V. Ideally, the capacitor should be able to withstand surges of 2kV.
Definitely use something larger than 0402 and rated for 50V. Ideally, the capacitor should be able to withstand surges of 2kV.