Wrs experience

Last edited by OHWR Gitlab support Mar 27, 2019
Page history

WRS Users experience

The experience of users of White Rabbit switches can give a good idea of the reliability and of the weakest parts in a switch.
This page therefore aims to collect data from the field about problems seen with switches.
To be able to get an idea of the percentage of switches that have failed, we try to keep track of the number of switches that are from the same installation of the ones that failed.

Note that the data has to be interpreted carefully. Many reported problems may be from early productions, from switches that have been used in labs, with open covers, many on/off cycles, changing SFPs etc. Furthermore this data is not exact as it does not track precisely the on-time, etc.

Again, this page is only to provide an idea to find out if there are any weak parts in the design that are needed to be addressed.

Reported failures

Date of failure Serial number Prod.date HW version Uptime (est) Environment Failure Remarks
26-07-2016 7S-WR-18P-3.4-3H_214 3.4 1 year CERN. Installed in experiment No power after operating for several months Short-circuit on T1 on minibackplane (so no PSU failure). Repaired under 7S-RMA-1607-WRS03.
2016 7S* -- 3.3 28 months GSI, Air-conditioned Lab Fan failure* The switch is installed in an open rack in an Air-conditioned Lab. Constant 21 grads
2016 7S* -- 3.3 28 months GSI, Stable Room Temp Fan failure* The switches are installed in open racks. The room has a stable temperature throughout the years ~ 21 grads
2016 7S* -- 3.3 25 months GSI, Stable Room Temp Fan failure* The switches are installed in open racks. The room has a stable temperature throughout the years ~ 21 grads
2016 7S* -- 3.4 20 months GSI, Air-conditioned Lab Fan failure* The switch is installed in an open rack in an Air-conditioned Lab. Constant 21 grads
2016 7S* -- 3.4 20 months GSI, Stable Room Temp Fan failure* The switches are installed in open racks. The room has a stable temperature throughout the years ~ 21 grads
2016 7S* -- 3.4 20 months GSI, Stable Room Temp Fan failure* The switches are installed in open racks. The room has a stable temperature throughout the years ~ 21 grads
2016 7S-WRS-18P-3.3-2H_034 -- 3.3 18 months GSI, Stable Room Temp Right fan failure The switches are installed in open racks. The room has a stable temperature throughout the years ~ 21 grads
2016 7S-WRS-18P-3.3-2H_058 -- 3.3 18 months GSI, Stable Room Temp Right fan failure The switches are installed in open racks. The room has a stable temperature throughout the years ~ 21 grads
2016 7S-WRS-18P-3.3-2H_067 -- 3.3 18 months GSI, Stable Room Temp Left fan failure The switches are installed in open racks. The room has a stable temperature throughout the years ~ 21 grads
2016 7S-WRS-18P-3.4-1H_108 -- 3.4 27 months GSI, Air-conditioned server racks FPGA fried We don't know what happen. The switch was down overnight. Repaired by 7S
2016 7S-WRS-18P-3.3-2H_067 -- 3.4 18 months GSI, Stable Room Temp 1 SFP Cage failure A. Rubini will give more details about it
2017 7S-WRS-18P-3.3-2H_065 -- 3.3 unknown CERN, used in lab with varying temp Does not lock to master, slaves have problems locking Very possibly, this is a production fault, users reported problems with nodes locking, we investigated and discovered the problem. Repaired under 7S-RMA-1704-WRS.
Cause: broken capacitor that grounded VCXO control signal.

*Unfortunately the fans were changed without writing down serial number or which fan was broken.

Purchased systems

User Number Version Manufacturer
GSI 24 3.3 Seven Solutions
GSI 58 3.4 Seven Solutions
GSI 13 3.4 Creotech
CERN

Installed systems (from which above reported failures come)

User Date Installed base Remarks Manufacturer
CERN January 2017 9 Installed in experiment.
GSI March 2017 13 Rack installed. Stable T Seven Solutions
GSI March 2017 13 GSI Lab. Room T 10 Seven Solutions 3 Creotech
GSI March 2017 5 GSI Timing Lab. Room T. Fans disconnected Seven Solutions

Remarks received

  • Since HW v3.4 the fans shipped within all WRS manufactured by 7S are Sunon MB40201VX-000U-A99 (MagLev with life expectancy > 8 years). Most of the FAN problems have been reported on WRS HWv3.3 **
  • Fans are problematic since most generic types have an MTBF of 3 to 5 years at room temperature and much less at elevated temperatures. (Nico Coesel)
  • We've used the 'MagLev' series fans from Sunon for a few projects (not on WRS - EB) and have not had a single failure ... yet. Reported MTBF's on these are on the order of 200,000 hours (~ 23 years). So, no bushings, no bearings, no problems. As an added benefit they are considerably quieter (mechanically) than even a good ball bearing fans - for applications where vibrations are important. (Tony Rohlev)

Observations

  • The official mechanics BOM reads that as fan this type is used by Seven Solutions: Gicoda MB40201VX-000U-A99.
  • "Gicoda MB40201VX-000U-A99" does not exist. It should be "Sunon MB40201VX-000U-A99" (Sunon, type number is the same). This is a DR MagLev = Dust-Resistance MagLev.
  • Creotech and Seven Solutions (since HW version 3.4) deliver both with the same "Sunon MB40201VX-000U-A99".
  • Creotech made one special serie only for GSI for evaluation with the Mechatronics G4020H12B-RSR that has a ball-bearing type.
  • Decided to stick to the "Sunon MB40201VX-000U-A99" for all productions.
  • ECIA Authorized search for MB40201VX-000U-A99
  • This type has Last time buy of 31 December 2017 (see EOL notice). "000U products are not recommended for new designs; all new designs should start with 1000U series. 1000U series have lower power consumption, lower dB(A)".
  • Recommended replacement type: MF40201VX-1000U-A99 (ECIA search)

11 October 2017

Files

  • MB40201VX-000U-A99_3.pdf
  • EOL_Notice_20160706.pdf
Clone repository
  • Documents
  • Home
  • Llf hlf
  • Modifying wrs firmware
  • Networking test
  • News
  • Production test
  • Wrs experience
  • Map
  • Wrs forwarding functions and performance tests
  • Wrs pts
  • Documents
    • Project attachments
    • Version 'wrs pts v1.0' attachments
    • Wrs pts documentation
More Pages

New Wiki Page

Tip: You can specify the full path for the new file. We will automatically create any missing directories.