Commit 4bde9828 authored by Adam Wujek's avatar Adam Wujek 💬 Committed by Grzegorz Daniluk

doc/wrs_failures: Add links to mentioned objects in general status objects

Signed-off-by: Adam Wujek's avatarAdam Wujek <adam.wujek@cern.ch>
parent b165798d
...@@ -40,7 +40,8 @@ ...@@ -40,7 +40,8 @@
\snmpentrys{WR-SWITCH-MIB}{wrsOSStatusGroup}{wrsBootSuccessful}{ \snmpentrys{WR-SWITCH-MIB}{wrsOSStatusGroup}{wrsBootSuccessful}{
\underline{Description:} \underline{Description:}
Grouped status of \texttt{wrsBootStatusGroup}, indicating whether boot was Grouped status of \texttt{\glshyperlink{WR-SWITCH-MIB::wrsBootStatusGroup}},
indicating whether boot was
successful. \texttt{Error} when dot-config source is wrong, unable to get successful. \texttt{Error} when dot-config source is wrong, unable to get
the dot-config, unable to get URL to the dot-config, dot-config contains the dot-config, unable to get URL to the dot-config, dot-config contains
errors, unable to read the hwinfo, unable to load the FPGA bitstream, unable errors, unable to read the hwinfo, unable to load the FPGA bitstream, unable
...@@ -128,9 +129,12 @@ ...@@ -128,9 +129,12 @@
\snmpentrys{WR-SWITCH-MIB}{wrsTimingStatusGroup}{wrsPTPStatus}{ \snmpentrys{WR-SWITCH-MIB}{wrsTimingStatusGroup}{wrsPTPStatus}{
\underline{Description:} \underline{Description:}
Reports the status of PTP daemon running on the switch.\\ Reports the status of PTP daemon running on the switch.\\
\texttt{Error} when any of PTP error counters in \texttt{wrsPtpDataTable}\\ \texttt{Error} when any of PTP error counters in
(\texttt{wrsPtpServoStateErrCnt}, \texttt{wrsPtpClockOffsetErrCnt} or\\ \texttt{\glshyperlink{WR-SWITCH-MIB::wrsPtpDataTable}}\\
\texttt{wrsPtpRTTErrCnt}) has increased since the last scan (issue (\texttt{\glshyperlink{WR-SWITCH-MIB::wrsPtpServoStateErrCnt.<n>}},
\texttt{\glshyperlink{WR-SWITCH-MIB::wrsPtpClockOffsetErrCnt.<n>}} or\\
\texttt{\glshyperlink{WR-SWITCH-MIB::wrsPtpRTTErrCnt.<n>}})
has increased since the last scan (issue
\ref{fail:timing:ppsi_track_phase}, \ref{fail:timing:ppsi_track_phase},
\ref{fail:timing:offset_jump}, \ref{fail:timing:rtt_jump}), at least one of \ref{fail:timing:offset_jump}, \ref{fail:timing:rtt_jump}), at least one of
the $\Delta_{TXM}$, $\Delta_{RXM}$, $\Delta_{TXS}$, $\Delta_{RXS}$ is 0 the $\Delta_{TXM}$, $\Delta_{RXM}$, $\Delta_{TXS}$, $\Delta_{RXS}$ is 0
...@@ -154,12 +158,17 @@ ...@@ -154,12 +158,17 @@
\snmpentrys{WR-SWITCH-MIB}{wrsTimingStatusGroup}{wrsSoftPLLStatus}{ \snmpentrys{WR-SWITCH-MIB}{wrsTimingStatusGroup}{wrsSoftPLLStatus}{
\underline{Description:} \underline{Description:}
Reports the status of the PLLs inside the switch.\\ Reports the status of the PLLs inside the switch.\\
\texttt{Error} when \texttt{wrsSpllSeqState} is not \emph{Ready}, or \texttt{Error} when \texttt{\glshyperlink{WR-SWITCH-MIB::wrsSpllSeqState}}
\texttt{wrsSpllAlignState} is not \emph{Locked} (for Grand Master mode), or is not \emph{Ready}, or
any of \texttt{wrsSpllHlock}, \texttt{wrsSpllMlock} equals to 0 (for \texttt{\glshyperlink{WR-SWITCH-MIB::wrsSpllAlignState}} is not
\emph{Locked} (for Grand Master mode), or any of
\texttt{\glshyperlink{WR-SWITCH-MIB::wrsSpllHlock}},
\texttt{\glshyperlink{WR-SWITCH-MIB::wrsSpllMlock}} equals to 0 (for
Boundary Clock mode).\\ Boundary Clock mode).\\
\texttt{Warning} when \texttt{wrsSpllDelCnt} $>$ 0 (for Grand Master mode) or \texttt{Warning} when \texttt{\glshyperlink{WR-SWITCH-MIB::wrsSpllDelCnt}}
\texttt{wrsSpllDelCnt} has changed (for all other modes).\\ $>$ 0 (for Grand Master mode) or
\texttt{\glshyperlink{WR-SWITCH-MIB::wrsSpllDelCnt}} has changed (for all
other modes).\\
\underline{On error:}\\ \underline{On error:}\\
For GrandMaster WRS: For GrandMaster WRS:
\begin{pck_proc} \begin{pck_proc}
...@@ -247,10 +256,12 @@ ...@@ -247,10 +256,12 @@
\underline{Description:} \underline{Description:}
Reports the status of SFP transceivers inserted to the switch.\\ Reports the status of SFP transceivers inserted to the switch.\\
\texttt{Error} when any of the SFPs reports an error. To find out which SFP \texttt{Error} when any of the SFPs reports an error. To find out which SFP
caused the problem check \texttt{wrsPortStatusSfpError.<n>}.\\ caused the problem check
\texttt{\glshyperlink{WR-SWITCH-MIB::wrsPortStatusSfpError.<n>}}.\\
\underline{On error:} \underline{On error:}
\begin{pck_proc} \begin{pck_proc}
\item Check \texttt{wrsPortStatusSfpError.*} SNMP objects or Syslog \item Check \texttt{\glshyperlink{WR-SWITCH-MIB::wrsPortStatusSfpError.<n>}}
SNMP objects or Syslog
messages to determine the WR port on which the problem is reported. In messages to determine the WR port on which the problem is reported. In
case of Syslog, you should see a message similar to this one:\\ case of Syslog, you should see a message similar to this one:\\
\texttt{Unknown SFP vn="AVAGO" pn="ABCU-5710RZ" vs="AN1151PD8A" on port \texttt{Unknown SFP vn="AVAGO" pn="ABCU-5710RZ" vs="AN1151PD8A" on port
...@@ -546,7 +557,7 @@ ...@@ -546,7 +557,7 @@
\snmpentrye{WR-SWITCH-MIB}{wrsPtpDataTable}{wrsPtpDeltaTxS.<n>}{} \snmpentrye{WR-SWITCH-MIB}{wrsPtpDataTable}{wrsPtpDeltaTxS.<n>}{}
\snmpentrye{WR-SWITCH-MIB}{wrsPtpDataTable}{wrsPtpDeltaRxS.<n>}{} \snmpentrye{WR-SWITCH-MIB}{wrsPtpDataTable}{wrsPtpDeltaRxS.<n>}{}
\snmpentrye{WR-SWITCH-MIB}{wrsPtpDataTable}{wrsPtpServoStateErrCnt.<n>}{ \snmpentrye{WR-SWITCH-MIB}{wrsPtpDataTable}{wrsPtpServoStateErrCnt.<n>}{
Number of the servo updates when servo is out of the TRACK\_PHASE.} Number of the servo updates when servo is out of the \texttt{TRACK\_PHASE}.}
\snmpentrye{WR-SWITCH-MIB}{wrsPtpDataTable}{wrsPtpClockOffsetErrCnt.<n>}{ \snmpentrye{WR-SWITCH-MIB}{wrsPtpDataTable}{wrsPtpClockOffsetErrCnt.<n>}{
Number of servo updates when offset is larger than 500ps or smaller than Number of servo updates when offset is larger than 500ps or smaller than
-500ps.} -500ps.}
......
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment