- Jan 10, 2020
-
-
Maciej Lipinski authored
There were few bug/problems: 1) Setting of tag/untag worked only when enabling tagging, if tagging was later set to disabled, this did not take effect. 2) This affected default configuration of tag/untag function when qmode of port was set. Thus, when changing to TRUNK from ACCESS, the port would keep untagging
-
Maciej Lipinski authored
-
Maciej Lipinski authored
The value of temperature that is read from register of the T100 sensor is encoded with twos complement on 16 bits. The encoding was not proper thus it worked fine but only for positive values of temperature. Added function that properly interprets the value of temp read from sensor's regsister.
-
- Jan 09, 2020
-
-
Jean-Claude BAU authored
Bug fix for PPS generation
-
- Jan 08, 2020
-
-
Jean-Claude BAU authored
Fix display errors for diagnostics
-
Grzegorz Daniluk authored
-
Grzegorz Daniluk authored
-
Grzegorz Daniluk authored
If it is disabled, it's commented out in dot-config, if it is enabled, it appears with "=y"
-
Grzegorz Daniluk authored
-
Grzegorz Daniluk authored
-
Grzegorz Daniluk authored
-
Grzegorz Daniluk authored
-
Grzegorz Daniluk authored
-
Grzegorz Daniluk authored
-
-
-
Grzegorz Daniluk authored
-
Grzegorz Daniluk authored
-
The fields in this table were not really filled in after substantial changes to the PPSi architecture regarding servo (HA-related). Filling in of the fields in this table had to be redone. This commit fixes filling in most of the fields that were field before. There are still some fields that are not filled in, tbd.
-
-
-
- update wrsSpllStatusGroup to recognize ver=3 - update wrsSpllStatusGroup and wrsSpllVersionGroup to properly complain to syslog when not recognizing version
-
Signed-off-by:
Adam Wujek <adam.wujek@cern.ch>
-
Move wrsPtpInstanceName to be the first (after indexes) OID. Thanks to this, by doing snmpwalk/snmpgetnext of OID wrsPtpInstanceName(.<n>.<m>), the user gets in a single responce: --n - a port number --m - an instance nubmer --value which is an instance name Signed-off-by:
Adam Wujek <adam.wujek@cern.ch>
-
Signed-off-by:
Adam Wujek <adam.wujek@cern.ch>
-
The list of VLANs is implemented as a string, becasue SNMP does not allow tables within tables. Signed-off-by:
Adam Wujek <adam.wujek@cern.ch>
-
Signed-off-by:
Adam Wujek <adam.wujek@cern.ch>
-
Signed-off-by:
Adam Wujek <adam.wujek@cern.ch>
-
Signed-off-by:
Adam Wujek <adam.wujek@cern.ch>
-
Signed-off-by:
Adam Wujek <adam.wujek@cern.ch>
-
Signed-off-by:
Adam Wujek <adam.wujek@cern.ch>
-
- Jan 07, 2020
-
-
Jean-Claude BAU authored
After a general cut in the electrical power supply, the switch can restart before than other generic systems (routeurs, serveurs, DHCP & NTP services,...). It results that the switch might be not well configured if these services cannot be reached and especially the DHCP service. So, a new behavior has been introduced to wait for the availability of the DHCP service (if configured) to get the source of the dot-config file and to setup the management port.
-
Jean-Claude BAU authored
A dependency have been added to not allow the option "Force to get the URL to a dot-config via DHCP" in order to get the source of the dot-config file. This option is now only available if the "DHCP forever" option is selected in the management port configuration. This has been done to avoid to wait forever the availability of the DHCP service to get the dot-config source while this service is not required or mandatory for the management port setup.
-
Jean-Claude BAU authored
When the configuration indicates that the network is forced to use the DHCP service for its setup (CONFIG_ETH0_DHCP=y), the script waits forever the availability of the DHCP service. In the other cases, the behavior remains unchanged.
-
Jean-Claude BAU authored
When the dot-config file is read at startup using the DHCP service to get the server IP address, the script waits forever the availability of DHCP service in the following case : - CONFIG_DOTCONF_SOURCE_FORCE_DHCP=y AND CONFIG_ETH0_DHCP=y CONFIG_ETH0_DHCP: Set to indicate that the network is forced to use DHCP for its setup. In the other cases, the behavior stay unchanged.
-
Jean-Claude BAU authored
The parser must take care of the help text because it can contains KConfig keywords. So, this fix identifies help sections and does not parse the help text.
-
- Dec 19, 2019
-
-
Jean-Claude BAU authored
-
- Dec 18, 2019
-
-
Jean-Claude BAU authored
-
- Dec 12, 2019
-
-
- Dec 10, 2019
-
-
Grzegorz Daniluk authored
-