Newer
Older
default n
help
Use hysteresis to control fans. Enable fans with PWM value
CONFIG_FAN_HYSTERESIS_PWM_VAL} when PLL's temperature exceeds
CONFIG_FAN_HYSTERESIS_T_ENABLE. Disable fans when temperature drops
below CONFIG_FAN_HYSTERESIS_T_DISABLE. These options are intended to
be used during development to reduce noise generated by a switch.
Don't use in production as this may affect the synchronization
performance.
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
config FAN_HYSTERESIS_T_DISABLE
int "Disable fans temperature"
default 60
range 0 80
depends on FAN_HYSTERESIS
help
Temperature at which fans are disabled when working in hysteresis mode.
config FAN_HYSTERESIS_T_ENABLE
int "Enable fans temperature"
default 65
range 0 80
depends on FAN_HYSTERESIS
help
Temperature at which fans are enabled when working in hysteresis mode.
Maximum allowed value is 80
config FAN_HYSTERESIS_PWM_VAL
int "Value of fans' PWM"
default 100
range 4 1000
depends on FAN_HYSTERESIS
help
PWM value used to drive fans. Range from 4 to 1000.
endmenu # "Fan speed control"
config READ_SFP_DIAG_ENABLE
bool "Read SFPs Diagnostic Monitoring"
default n
help
Let HAL to read Diagnostic Monitoring from SFP's eeprom.
endmenu # "Developer options"
menu "RTU HP mask"
config RTU_HP_MASK_ENABLE
bool "Set custom High Priority mask in RTU"
default n
help
Set the mask which priorities are considered High Priority (this
only concerns the traffic which is fast-forwarded).
config RTU_HP_MASK_VAL
string "HP mask"
default 0
depends on RTU_HP_MASK_ENABLE
help
Mask with priorities (eg. 0x9 => priority 4 and 0 are considered HP)
endmenu