dbde4a22 · Update .ohwr.yaml
-
83b127b1 · Update .ohwr.yaml
opened
issue
#62
"Increase 5V OCP Threshold"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
-
8befcbc6 · Update .ohwr.yaml
-
2057097a · Update .ohwr.yaml
opened
issue
#61
"Change the current PTC Thermistor to PT 500"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
opened
issue
#60
"Increase spacing between T1 and T2, increase thermal pad"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
opened
issue
#59
"Change the zener diode (BZV55-B12) to BZV55-B13 (13V variant)"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
closed
issue
#28
"DC input contacts inverted"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
commented on
issue #28
"DC input contacts inverted"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
Fixed in EDMS EDA-04422-V4
closed
issue
#29
"DCDC: add a small resistor to load the 5V and avoid oscillation when there is no card in the chassis"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
commented on
issue #29
"DCDC: add a small resistor to load the 5V and avoid oscillation when there is no card in the chassis"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
Fixed in EDMS EDA-04422-V4
closed
issue
#30
"modify shutdown circuit to allow for full discharge and 12V drop to 0V before restarting"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
commented on
issue #30
"modify shutdown circuit to allow for full discharge and 12V drop to 0V before restarting"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
Fixed in EDMS EDA-04422-V4
closed
issue
#31
"shall we have and ORing diode for redundant operation?"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
commented on
issue #31
"shall we have and ORing diode for redundant operation?"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
Fixed in EDMS EDA-04422-V4
closed
issue
#32
"Current sense circuit is not linear from 50mA to 500mA"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
commented on
issue #32
"Current sense circuit is not linear from 50mA to 500mA"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply
Fixed in EDMS EDA-04422-V4
closed
issue
#33
"Current share line shuts down the second RaToPUS"
at
Projects / RaToPUS radiation-tolerant AC-DC power supply