Skip to content
Snippets Groups Projects
Select Git revision
  • controls
  • feature/UI_Plots
  • feature/setup_instructions
  • feature/ui_battery_display
  • feature/ui_full_screen_popups
  • feature/ui_localisation
  • feature/ui_visuals
  • fix-gitlab-ci
  • hevclient-refactor
  • hevserver-code-cleanup
  • hplv_new_commands
  • master default protected
  • release/CPAP
  • release/VC_MODE
  • release/new_state_machines
  • release/ui
  • test/software_intro
  • test/software_intro2
  • test_UI_new_state_machines_merge
  • ui_debug1
20 results
You can move around the graph by using the arrow keys.
Created with Raphaël 2.2.027Jan262215141312876417Dec168730Nov1716114216Oct14Aug1312659Jul7629Jun26252423191815121110989876543432131May292827262524232221201918171615141312118765432130Apr29282928Merge branch 'ui_dev' of https://ohwr.org/project/hev into ui_devRevert "test"testfully mergedmergedtestingWIP measurement widgets and new hev_main layout. Also added placeholders for page and start/stop/standby buttonsadjusted ADC2 calibration for O2 sensorfio2_est is stored in I/E variable, O2 sensor in fio2_percentMerge branch 'fix-gitlab-ci' into 'master'Fix gitlab ci in ohwr repo for auto compilationomitted overshooting in INCREASE_O2 state and corrected calculation of o2_frac_pressureAdded timeout between O2 valve closing and air valve opening. adjusted MAINTAIN_O2 state to ignore p_buff_lower until O2 AND air are filled.Revert "Test commit to confirm local branch is set up correctly"Test commit to confirm local branch is set up correctlymoved calculations to seperate function, corrected minor errorsadded DECREASE_O2 state, corrected minor bugs, seemed to workincluded check if p_buff was decreasing when fillingmoved assignFillFSM into doBreathFSM function, O2_sensor reads estimated valueminor bugsimplemented controlled O2 valve opening, estimation of O2 concentrationWIP: adding O2 valve control to FILL fsmrenamed FSM functions and cleaned codeminor bugs in valves closing/opening logictwo seperate functions for breathe valves and fill valves. new fill fsm state PURGEChanged state names of fill FSM and simplified air fill stateAdded Fill_FSM with two states. new function to control only O2, air and purge valveMerge branch 'fix/varying_measurement_frequency' into 'master'small adjustment of variableChanged the calculation of the voltage from adc according to measured Voltag/ADC factorcommented ui loop reportsMerge branch 'master' of https://ohwr.org/project/hevcorrected calculation of pressure sensoradd timestamp to logmsgTidy up imports in hevserver and utilsRemove legacy code - outdated front end emulatorsRename CommsFormat->CommsPacket to reflect contentsRefactor CommsFormatMerge branch 'master' of https://ohwr.org/project/hevupdates to flow and volume calculation