Commit 389e5fce authored by Theodor-Adrian Stana's avatar Theodor-Adrian Stana

doc: Added input and output termination figures to user guide

parent 47ecbadb
This diff is collapsed.
This diff is collapsed.
......@@ -321,16 +321,18 @@ Each RS-485 output on a channel has its dedicated transceiver capable of driving
each input and output channel has a selectable 100~$\Omega$ termination, which can be enabled by the
input and output termination switches (see Section~\ref{sec:switches}). Setting the input or output
termination enable switch to the ON position enables a connection via a solid-state relay, which in turns
enables the termination connection as shown in Figures~\ref{fig:iterm}~and~\ref{fig:oterm}.
enables the termination connection as shown in Figures~\ref{fig:oterm}~and~\ref{fig:iterm}.
Finally, when a pulse is repeated on the output connector of a channel, the pulse status LED flashes briefly.
\begin{figure}[h]
% \centerline{\includegraphics[width=.6\textwidth]{fig/iterm}}
% \caption{\label{fig:iterm} Input termination enable}
\centerline{\includegraphics[width=.8\textwidth]{fig/oterm}}
\caption{\label{fig:oterm} Output termination enable}
\end{figure}
\centerline{\includegraphics[width=.6\textwidth]{fig/oterm}}
\caption{\label{fig:iterm} Output termination enable}
\begin{figure}[h]
\centerline{\includegraphics[width=.8\textwidth]{fig/iterm}}
\caption{\label{fig:iterm} Input termination enable}
\end{figure}
%======================================================================================
......
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment