GM input stage temperature dependance
The temperature dependance in the GM mode of the input stage (buffer + LMX2594) has been measured to be ~6 ps / C degree, see report: LMX_temperature_test.pdf It is much more than reported in the tests performed by Mattia (page 28 of WRS-4_main_board_Hardware_Architecture_-v1.7-2020-06-09.pdf):