Commit 2a4da7db authored by Wesley W. Terpstra's avatar Wesley W. Terpstra

ep_tx_pcs_8bit: transfer an_tx_en safely between sys->tx domains

On Altera platforms this bug manifests as the minic failing to TX packets
correctly and the whole PTP state machine grinding to a halt.

This was already fixed in the 16bit version.
parent fa85ad04
......@@ -154,6 +154,7 @@ architecture behavioral of ep_tx_pcs_8bit is
signal reset_synced_txclk : std_logic;
signal mdio_mcr_pdown_synced : std_logic;
signal an_tx_en_synced : std_logic;
signal s_one : std_logic := '1';
......@@ -194,6 +195,15 @@ begin
rst_n_i => '1',
data_i => mdio_mcr_pdown_i,
synced_o => mdio_mcr_pdown_synced);
U_sync_tx_en : gc_sync_ffs
generic map (
g_sync_edge => "positive")
port map (
clk_i => phy_tx_clk_i,
rst_n_i => '1',
data_i => an_tx_en_i,
synced_o => an_tx_en_synced);
phy_tx_data_o <= tx_odata_reg;
phy_tx_k_o <= tx_is_k;
......@@ -288,7 +298,7 @@ begin
tx_error <= '0';
-- endpoint wants to send Config_Reg
if(an_tx_en_i = '1') then
if(an_tx_en_synced = '1') then
tx_state <= TX_CR1;
tx_cr_alternate <= '0';
fifo_rd <= '0';
......@@ -370,7 +380,7 @@ begin
tx_odata_reg <= an_tx_val_i(15 downto 8);
-- check if the autonegotiation control still wants the Config_Reg to be sent
if(an_tx_en_i = '1') then
if(an_tx_en_synced = '1') then
tx_state <= TX_CR1;
else
tx_state <= TX_COMMA;
......