# Frequently Asked Questions
|
|
|
|
|
|
about the White Rabbit
|
|
|
switch.
|
|
|
# Frequently Asked Questions
|
|
|
about the White Rabbit switch.
|
|
|
|
|
|
|
|
|
## Connecting the switch to an external GPS receiver
|
... | ... | @@ -34,12 +32,19 @@ we mean the messages generated by the LM32 CPU inside the Virtex FPGA. |
|
|
They may provide useful information for debugging the timing subsystem.
|
|
|
They can be viewed by connecting a serial terminal to the the front left
|
|
|
USB port (up to v. 3.2 switches) or the "FPGA test" USB port in the rear
|
|
|
(newer switches). RS232 parameters are 115200, 8N1.
|
|
|
(newer switches). RS232 parameters are 115200,
|
|
|
8N1.
|
|
|
|
|
|
-----
|
|
|
|
|
|
## General questions
|
|
|
|
|
|
### Q: Should green and orange LEDs be lit when copper SFP is used even without Ethernet cable plugged in ?
|
|
|
|
|
|
A: Yes, that is the normal behavior with most of the copper SFPs. Even
|
|
|
after unplugging Ethernet cable the copper SFP fakes an active
|
|
|
connection so green LED is ON and orange may be blinking.
|
|
|
|
|
|
### Q: does the switch comply to CE regulations (EMC)?
|
|
|
|
|
|
A: It is. The company Seven Solutions has performed extensive EMC tests
|
... | ... | @@ -48,15 +53,9 @@ switch. |
|
|
|
|
|
-----
|
|
|
|
|
|
### Q: If I don’t participate in WR workshop meetings, is the presentation material still available?
|
|
|
## White Rabbit general questions
|
|
|
|
|
|
A: All we do is public. All [information from the workshops](/Workshops)
|
|
|
is
|
|
|
public.
|
|
|
|
|
|
-----
|
|
|
|
|
|
### Q: How can I test White Rabbit equipment? Or I can I buy some test equipments from your company?
|
|
|
### Q: How can I test White Rabbit switch equipment? Or I can I buy some test equipments from your company?
|
|
|
|
|
|
A: CERN is not a company, but a publicly funded intergovernemental
|
|
|
organization. We develop the technology but don't produce the equipment,
|
... | ... | @@ -70,17 +69,14 @@ the companies from which you can buy a WR switch (Commercial producers, |
|
|
at the bottom). On the [wiki page about SPEC
|
|
|
card](https://www.ohwr.org/project/spec/wiki) (an example of WR Node)
|
|
|
you will find companies producing SPEC cards.
|
|
|
For starting to play with WR technology, very soon a "WR started kit"
|
|
|
will be available, see [WR node wiki page](/Node) for
|
|
|
details.
|
|
|
For starting to play with WR technology, a [WR starting
|
|
|
kit](https://www.ohwr.org/project/wr-starting-kit/wiki) is
|
|
|
available.
|
|
|
|
|
|
-----
|
|
|
|
|
|
### Q: Should green and orange LEDs be lit when copper SFP is used even without Ethernet cable plugged in ?
|
|
|
### Q: If I don’t participate in WR workshop meetings, is the presentation material still available?
|
|
|
|
|
|
A: Yes, that is the normal behavior with most of the copper SFPs. Even
|
|
|
after unplugging Ethernet cable the copper SFP fakes an active
|
|
|
connection so green LED is ON and orange may be blinking.
|
|
|
A: All we do is public. All [information from the workshops](/Workshops)
|
|
|
is public.
|
|
|
|
|
|
-----
|
|
|
|
... | ... | |