## Introduction
|
|
|
|
|
|
The requirement for XP applications is to measure very low levels of UV.
|
|
|
Most of the sensors on the market are for high levels (for warning of
|
|
|
getting a sunburn on normal skin), and so cannot be used.
|
|
|
|
|
|
### Requirements
|
|
|
|
|
|
- Resolution of 0.001 MED/hr or better
|
|
|
|
|
|
-----
|
|
|
|
|
|
## UV meter
|
|
|
|
|
|
- [Solarmeter](http://www.solarmeter.com)
|
|
|
- [Model 5.7 UV meter](http://www.solarmeter.com/model57.html)
|
|
|
(demonstrated)
|
|
|
- [Model 7.0 UV meter](http://www.solarmeter.com/model7.html)
|
|
|
(MED/HR ERYTHEMALLY Effective (Eeff) UVR)
|
|
|
- Resolution 1 µW/cm²
|
|
|
- Irradiation range 0-1999 µW/cm² Total UV
|
|
|
- <s>[Model 7.0 UV meter](http://www.solarmeter.com/model7.html)
|
|
|
(MED/HR ERYTHEMALLY Effective (Eeff) UVR)</s>
|
|
|
- The Model 7.0 has a resolution of 0.1 MED/hr whereas we need
|
|
|
0.001 or preferably better.
|
|
|
|
|
|
<!-- end list -->
|
|
|
|
... | ... | @@ -18,14 +34,40 @@ |
|
|
- Also available as the UV MINDER® Model 3D-XP Xeroderma Erythemal
|
|
|
UV Intensity Meter for measuring very low UV intensity to 3
|
|
|
decimal places
|
|
|
- Readout range: 0...19.99 MED/Hr (standard model, the Xeroderma
|
|
|
Erythemal UV Intensity Meter has one more decimal place).
|
|
|
- *There is no datasheet of the Xeroderma Erythemal UV Intensity
|
|
|
Meter model*
|
|
|
- It is this model that is used as reference. It has only one
|
|
|
detector, mounted in the middle of the device.
|
|
|
|
|
|
*Note**
|
|
|
|
|
|
- Arduino UV sensor have typically a resolution of 1 UV factor i.e. 1
|
|
|
MED/hr, so cannot be used.
|
|
|
|
|
|
-----
|
|
|
|
|
|
## Units
|
|
|
|
|
|
- Minimal Erythemal Doses per Hour (MED/Hr)
|
|
|
- The shortest exposure to ultraviolet radiation that produces
|
|
|
reddening of the skin within 1 to 6 hr and disappears in 24
|
|
|
hr.
|
|
|
The minimal erythemal dose is used to calculate the duration of
|
|
|
therapeutic exposure to ultraviolet light. For treatment using a
|
|
|
“hot” ultraviolet lamp (UV-A or UV-B), the dose is calculated at
|
|
|
a distance of 30 in. The minimal erythemal dose for “cold”
|
|
|
ultraviolet (UV-C) is standardized at 30 to 38 sec at a distance
|
|
|
of 1 in. Synonym: erythema dose; threshold dose (from
|
|
|
[thefreedictionary.com](http://medical-dictionary.thefreedictionary.com/minimum+erythema+dose)
|
|
|
|
|
|
-----
|
|
|
|
|
|
## Calibration methods
|
|
|
|
|
|
- research needed
|
|
|
- NIST standard (*reference needed*)
|
|
|
- Relationship between µW/cm² and MED/hr (*reference needed*)
|
|
|
|
|
|
-----
|
|
|
|