# RaToPUS, radiation tolerant AC-DC power supply
|
|
|
|
|
|
## Project description
|
|
|
|
|
|
Radiation-tolerant AC/DC power supply unit (PSU). In: 230VAC, 50Hz, Out: +12V, 8.33A (100W) and +5V, 2A (10W). Possibility for redundancy. The design is CompactPCI compatible. Part of DIOT project.
|
|
|
**Disclaimer:**<br>
|
|
|
**Manufacturing the power supply according to the design published in this project does not ensure it will be resistant to radiation. Only using the components from a lot qualified in irradiation campaign guarantees that this power supply will withstand the radiation levels mentioned in the specification.**
|
|
|
|
|
|
**Below is only a template.
|
|
|
Please update using the [recommended setup and usage guide](https://www.ohwr.org/project/ohr-support/wikis/Administrator-guide#recommended-setup-usage)**
|
|
|
## Project description
|
|
|
|
|
|
![](/uploads/23a127884e2820d707e58c6119cde69d/spec_v1.1_top.JPG)
|
|
|
*SPEC 1.1 first prototype**
|
|
|
RaToPUS is a 100W AC/DC power supply compatible with the CompactPCI-Serial standard (CPCI-S.0). It is designed in the frame of the Distributed I/O Tier project to be used in radiation-exposed installations of the HL-LHC at CERN.
|
|
|
|
|
|
## Main Features
|
|
|
|
|
|
- 4-lane PCIe (Gennum GN4124) *obsolete component, not available
|
|
|
anymore*
|
|
|
- 1x Xilinx Spartan6 FPGA (XC6SLX45T-3FGG484C) (PCI Device ID: 0x18D)
|
|
|
- special versions with XC6SLX100T and XC6SLX150T available
|
|
|
- FMC slot with low pin count (LPC) connector
|
|
|
- Vadj fixed to 2.5V
|
|
|
- FMC connectivity: all 34 differential pairs connected, 1 GTP
|
|
|
transceiver with clock, 2 clock pairs, JTAG, I2C
|
|
|
- No dedicated clock signals from Carrier to FMC (only available
|
|
|
on HPC pins)
|
|
|
- Stand-alone features
|
|
|
- External 12V power supply connector
|
|
|
- mini USB connector
|
|
|
- 4 LEDs
|
|
|
- 2 buttons
|
|
|
- Power consumption: 5-12 Watt, depending on application
|
|
|
- Optimised for cost
|
|
|
- 6-layer PCB
|
|
|
- Optional cooling [fan](Fan-Design) for the mezzanine.
|
|
|
| Parameter | Value |
|
|
|
| ------ | ------ |
|
|
|
| Input | Nominal: 230Vac, 0.5A <br> Range: 90-265 Vac, 50-60 Hz |
|
|
|
| Outputs | 12V, 8.33A, 100W – Payload channel <br> 5V, 2A, 10W – Standby channel |
|
|
|
| Output voltage ripple + noise <br> (pk-pk value) | 100mVpp for 12V <br> 20mVpp for 5V |
|
|
|
| Regulation: Line <br> Regulation: Load | ±2% <br> ±2% |
|
|
|
| Efficiency | ≥80% at 230 Vac |
|
|
|
| Active PFC | ≥0.98 |
|
|
|
| Switching frequency | 250 kHz - 1 MHz |
|
|
|
| Transient response | 10% maximum deviation; <br> Returns to nominal Vo in 1 ms maximum.|
|
|
|
| Total Ionizing Dose (TID) | ≥500 Gy |
|
|
|
| PCB dimensions | 100 mm x 160 mm x 37 mm |
|
|
|
| PSU dimensions (including packaging) | 3U x 170mm x 8HP (133mm x 170mm x 40mm |
|
|
|
| External monitoring | PMBus: Conveys output voltages, output currents, temperature |
|
|
|
| External control | PS_ON pin for remote switching ON/OFF |
|
|
|
| EMI specifications | EN55022 Class B |
|
|
|
| Thermal environment:<br>- Ambient temperature<br>- Active cooling | <br>40ºC<br>No |
|
|
|
| Redundancy/load sharing | Passive (droop-based) |
|
|
|
|
|
|
-----
|
|
|
## Architecture
|
|
|
RaToPUS is designed in two stages:
|
|
|
- AC/DC stage: 230VAC to 48VDC
|
|
|
- isolated DC/DC stage: 48VDC to 12VDC and 5VDC
|
|
|
|
|
|
## Project information
|
|
|
![RaToPUS_architecture](uploads/66f51c94432aee02d2dc34853ff8f936/RaToPUS_architecture.png)
|
|
|
|
|
|
- Official production documentation: [EDMS EDA-02189](http://edms.cern.ch/nav/eda-02189)
|
|
|
- [Users](Users)
|
|
|
- [Software](Software)
|
|
|
- [Fan design](Fan-Design)
|
|
|
- [Frequently Asked Questions](FAQ)
|
|
|
|
|
|
-----
|
|
|
## Related links and documents
|
|
|
|
|
|
## Releases
|
|
|
- [CompactPCI-Serial standard](https://www.picmg.org/openstandards/compactpci-serial/)
|
|
|
- [FEAST2.1 datasheet](http://project-dcdc.web.cern.ch/project-dcdc/public/Documents/FEAST2.1%20datasheet.pdf)
|
|
|
|
|
|
- Hardware
|
|
|
- [SPEC V4-0](https://edms.cern.ch/nav/EDA-02189-V4-0)
|
|
|
- [SPEC V4-1: same V4-0 base board with additional board
|
|
|
supporting a fan](https://edms.cern.ch/nav/EDA-02189-V4-1)
|
|
|
- Only needed in badly ventilated PCs using highly dissipating
|
|
|
cards such as the [FMC
|
|
|
DEL 1ns 4cha](https://www.ohwr.org/project/fmc-delay-1ns-8cha/wiki)
|
|
|
|
|
|
-----
|
|
|
|
|
|
## Contacts
|
|
|
|
|
|
### Commercial producers
|
|
|
|
|
|
- [SPEC](http://creotech.pl/en/produkt/en-simple-pcie-fmc-carrier-spec/)
|
|
|
[Creotech](http://www.creotech.pl), Poland
|
|
|
|
|
|
|
|
|
### General questions about project
|
|
|
|
|
|
- [Erik van der Bij](mailto:Erik.van.der.Bij@cern.ch) - CERN
|
|
|
|
|
|
-----
|
|
|
* [Greg Daniluk](mailto:grzegorz.daniluk@cern.ch) - CERN
|
|
|
* [Lalit Patnaik](mailto:lalit.patnaik@cern.ch) - CERN
|
|
|
|
|
|
## Status
|
|
|
|
|
|
| Date | Event |
|
|
|
| --------- | ------ |
|
|
|
| 10-01-2018| Start working on project. Collecting main specifications.|
|
|
|
| 12-01-2018| Main specifications collected. |
|
|
|
|
|
|
-----
|
|
|
|
|
|
Erik van der Bij - 19 December 2018 |
|
|
\ No newline at end of file |
|
|
| Sep-2018| Start working on project. Collecting main specifications.|
|
|
|
| Jan-2019| First prototype of non-isolated 10W DC-DC stage | |
|
|