- 05 Jul, 2021 1 commit
-
-
Adam Wujek authored
Signed-off-by: Adam Wujek <dev_public@wujek.eu>
-
- 29 Jun, 2021 4 commits
-
-
Adam Wujek authored
Signed-off-by: Adam Wujek <dev_public@wujek.eu>
-
Adam Wujek authored
Could result in a servo stuck after re-sync that happens every ~49.7days. Signed-off-by: Adam Wujek <dev_public@wujek.eu>
-
Adam Wujek authored
Signed-off-by: Adam Wujek <dev_public@wujek.eu>
-
Adam Wujek authored
This reverts commit ba107c11. The mentioned commit has been reverted because timeouts did not work correctly at the overflow causing the WRS to resync and sometimes stuck after ~49.7 days (and multiplies) after boot.:
-
- 12 Jun, 2020 1 commit
-
-
Maciej Lipinski authored
-
- 15 May, 2020 1 commit
-
-
Grzegorz Daniluk authored
-
- 25 Mar, 2020 1 commit
-
-
Jean-Claude BAU authored
This calculation is done using the timestamps but without any correction.
-
- 06 Mar, 2020 1 commit
-
-
Jean-Claude BAU authored
-
- 04 Mar, 2020 1 commit
-
-
Jean-Claude BAU authored
-
- 24 Feb, 2020 2 commits
-
-
Jean-Claude BAU authored
-
Jean-Claude BAU authored
The delayMS in PS was not set in the WR servo.
-
- 20 Feb, 2020 1 commit
-
-
Jean-Claude BAU authored
When a transition of a interface form up->down->up occured, the Slave port was restarted sometimes with the extension OFF. It has been fixed by re-enabling the extension when a transition state from SLAVE to UNCALIBRATED is detected.
-
- 07 Feb, 2020 1 commit
-
-
Jean-Claude BAU authored
Fix problem related to code optimization
-
- 06 Feb, 2020 2 commits
-
-
Jean-Claude BAU authored
-
Jean-Claude BAU authored
-
- 03 Feb, 2020 10 commits
-
-
Jean-Claude BAU authored
The conversion has been fixed now for negative values.
-
Jean-Claude BAU authored
-
Jean-Claude BAU authored
-
Jean-Claude BAU authored
-
Jean-Claude BAU authored
The detection of a new parent has been moved in a call back of the S1 treatment. The previous implementation had some side effect due to the fact that the detection was coming too late in some cases (pb with erbest calculation) The doRestart called by the servo is now extension specific. It help to make a more cleaner restart.
-
Jean-Claude BAU authored
The calculation of the erbest is no longer called if ExternalPortConfiguration is enabled. The erbest is set when a new foreign master is added.
-
Jean-Claude BAU authored
The S1 treatment must be called only if the foreign master is accepted/registered by the BMCA.
-
Jean-Claude BAU authored
-
Jean-Claude BAU authored
-
Jean-Claude BAU authored
- In case of handshake failure due to the reception of an unexpected message, execute the same procedure executed in case of time-out. The behavior will be more coherent. - better diagnostics
-
- 28 Jan, 2020 1 commit
-
-
Alessandro Rubini authored
This version of ppsi, currently submodule of proposed_master of wr-switch-sw, is not building because of INT_MAX, UINT_MAX and the like. This includes <limits.h> in all files where this is needed. Obviously, <limits.h> will be missing in wrpc-sw and bare builds, but this version does not build for most architectures anyways (including arch-unix). Signed-off-by: Alessandro Rubini <rubini@gnudd.com>
-
- 17 Jan, 2020 1 commit
-
-
Jean-Claude BAU authored
Bug description : When a MASTER port is at a lower port number than a SLAVE port, the SLAVE port is jumping all the time between UNCALIBRATED and SLAVE state.
-
- 09 Jan, 2020 1 commit
-
-
Jean-Claude BAU authored
-
- 08 Jan, 2020 1 commit
-
-
Jean-Claude BAU authored
The 2 octets were displayed as as int16 so they can be swapped depending of the architecture.
-
- 19 Dec, 2019 1 commit
-
-
Jean-Claude BAU authored
When the PPS generation is forced by configuration, the PPS was disabled when an instance was leaving the UNCALIB/SLAVE states to another state.
-
- 18 Dec, 2019 1 commit
-
-
Jean-Claude BAU authored
-
- 13 Dec, 2019 3 commits
-
-
Jean-Claude BAU authored
- When a new GM has been detected by the BMCA, the SLAVE state must transition to UNCALIBRATED. If the state is already set to UNCALIBRATED , nothing must be done.
-
Jean-Claude BAU authored
-
Jean-Claude BAU authored
- All announce messages not received from erbest are not been taken into account. erbest is the best qualified foreign master. - Comments added
-
- 20 Nov, 2019 2 commits
-
-
Jean-Claude BAU authored
-
Jean-Claude BAU authored
Introduction of an other way to calculate the best foreign master. It has been changed to fix bugs found during ISPC20119 (IOL test). Tests showed unstable behavior in the computation of foreign master qualification in some specific circumstances (time window of 8s with announce messages every 5s)
-
- 15 Nov, 2019 1 commit
-
-
Jean-Claude BAU authored
Issue detected by IOL test in ICALEPS2019 The selection of the ErBest was not taking account all the time of the qualification.
-
- 14 Nov, 2019 1 commit
-
-
Jean-Claude BAU authored
- New mechanism for clock degradation (degrade clock class, clock accuracy, clock variance, timeSource, ptpTimeScale, frequencyTraceable, timeTraceable) - timeSource can be configured now - If clock accuracy, clock variance and timeSource are not set in ppsi.conf, default values are used depending of the clock class.
-
- 11 Nov, 2019 1 commit
-
-
Jean-Claude BAU authored
Change clock accuracy from 0x21(100ns) to 0x20(25ns) for ARB Grand Master.
-