Pull up resistor to to be removed
On the V2.0, the functionality of voltage translators is affected by the presence of pull ups on the CS of DACs and ADCs, so R39, R42, R45 and R48 must be declared as NOT MOUNTED.
On the V2.0, the functionality of voltage translators is affected by the presence of pull ups on the CS of DACs and ADCs, so R39, R42, R45 and R48 must be declared as NOT MOUNTED.