... | ... | @@ -32,6 +32,8 @@ considered measurement error) |
|
|
|
|
|
## Detailed temperature measurements on different platforms:
|
|
|
|
|
|
*Note:** All temperatures in degrees Celsius.
|
|
|
|
|
|
### **Test environment**
|
|
|
|
|
|
\- VME: Wiener and Elma crates, with up to 7 SVECs (14 Fine Delays)
|
... | ... | @@ -39,16 +41,22 @@ installed in subsequent slots. Whenever possible, different |
|
|
combinations
|
|
|
of VME slots and fan speeds were used.
|
|
|
|
|
|
\- PCI Express: Kontron industrial PC, with 5 SPECs and 5 Fine Delays.
|
|
|
\- Ambient temperature: 26 - 28 degrees Celsius.
|
|
|
\- PCI Express: Kontron industrial PC, with 5 SPECs and 5 Fine Delays.
|
|
|
|
|
|
\- Ambient temperature: 26 - 28.
|
|
|
\- Temperatures were logged over time to make sure they have settled up
|
|
|
before. The first stable sample (with less than 1 degree temperature
|
|
|
change over 1 minute) was used for the statistics.
|
|
|
|
|
|
### **Data:**
|
|
|
|
|
|
*Wiener 21-slot VME64x crate:**
|
|
|
|
|
|
Slots 4-10
|
|
|
| Slot/FMC | 4/1 | 4/2 | 5/1 | 5/2 | 6/1 | 6/2 | 7/1 | 7/2 | 8/1 | 8/2 |
|
|
|
9/1 | 9/2 | 10/1 | 10/2 |
|
|
|
Slots 4-10:
|
|
|
| **Slot/FMC** | 4/1 | 4/2 | 5/1 | 5/2 | 6/1 | 6/2 | 7/1 | 7/2 | 8/1 |
|
|
|
8/2 | 9/1 | 9/2 | 10/1 | 10/2 |
|
|
|
| **Temperature** | 65.69 | 71.38 | 56.88 | 66.25 | 50.69 | 63.88 |
|
|
|
51.19 | 63.62 | 58.62 | 73.25 | 61.44 | 71.00 | 50.12 | 59.62 |
|
|
|
|
|
|
*Conclusions**
|
|
|
|
... | ... | |