... | ... | @@ -39,8 +39,13 @@ Ambient temp 19-20. |
|
|
|
|
|
\- Temperatures were logged over time to make sure they have settled up
|
|
|
before taking measurements. The first stable sample (with less than 1
|
|
|
degree temperature change over 1 minute) was used for the statistics.
|
|
|
\- Unused slots were covered to ensure maximum airflow through the FMCs.
|
|
|
degree temperature change over 1 minute) was used for the statistics.
|
|
|
|
|
|
\- Unused slots were covered to ensure maximum airflow through the
|
|
|
FMCs.
|
|
|
\- PXI Express: National Instruments crates: 3 slots (PXIe-1071) at
|
|
|
ambient temp 25C and 8 slots (PXIe-1062Q) at ambient temp 29C with one
|
|
|
Fine Delay in different slots.
|
|
|
|
|
|
### Data (cards without heatsinks):
|
|
|
|
... | ... | @@ -449,6 +454,11 @@ Slots 10-15: |
|
|
| **Slot** | 1 | 2 | 3 | 7 | 8 |
|
|
|
| **Temp** | 88.19 | 81.94 | 89.12 | 83.0 | 71.75 |
|
|
|
|
|
|
*National Instruments 3-slot PXIe crate**
|
|
|
| **Fans** | **Slot/FMC** | 2/1 | 2/2 | 3/1 | 3/2 |
|
|
|
| Auto | **Temp** | 57.2 | 55.5 | 55.2 |
|
|
|
| Max | | 48.7 | 47.9 | 46.82 |
|
|
|
|
|
|
### Summary
|
|
|
|
|
|
<table>
|
... | ... | |