# Heatsinks for the FMC Fine Delay
|
|
|
|
|
|
This page summarizes the heatsink testing results.
|
|
|
This page summarizes the heatsink testing results. All tests made with
|
|
|
version EDA-02267-V6-0.
|
|
|
|
|
|
## Fine Delay on SVEC (lab test)
|
|
|
|
... | ... | @@ -229,8 +230,9 @@ needed. |
|
|
|
|
|
## Thermal imaging
|
|
|
|
|
|
tbc
|
|
|
h2. Thermal camera measurements
|
|
|
tbc
|
|
|
|
|
|
## Thermal camera measurements
|
|
|
|
|
|
## Replacing the LVPECL delay lines with LVDS counterparts
|
|
|
|
... | ... | @@ -239,8 +241,17 @@ with an LVDS version: ICS854S296I-33. Temperature test |
|
|
(identical conditions) performed on a SVEC showed 5 degrees less on the
|
|
|
modified card:
|
|
|
|
|
|
\- new delay line 51.31 Celsius
|
|
|
\- old delay line 56.38 Celsius
|
|
|
- new delay line (LVDS) 51.31 Celsius
|
|
|
- old delay line (PECL) 56.38 Celsius
|
|
|
|
|
|
Note that the EDA-02267-V6-0 PCB is not foreseen for the LVPECL
|
|
|
termination resistors for the new delay line chip. In case we decide to
|
|
|
use the new chip, for production purposes a new revision of the PCB
|
|
|
should be made.
|
|
|
|
|
|
-----
|
|
|
|
|
|
15 August 2014
|
|
|
|
|
|
|
|
|
|
... | ... | |