... | ... | @@ -51,7 +51,7 @@ before taking measurements. The first stable sample (with less than 1 |
|
|
degree temperature change over 1 minute) was used for the statistics.
|
|
|
\- Unused slots were covered to ensure maximum airflow through the FMCs.
|
|
|
|
|
|
### Data:
|
|
|
### Data (without heatsinks):
|
|
|
|
|
|
*Wiener 21-slot VME64x crate, fans at 1200 rpm (minimum speed):**
|
|
|
|
... | ... | @@ -124,6 +124,31 @@ Slots 9-15: |
|
|
</tbody>
|
|
|
</table>
|
|
|
|
|
|
### Data (with heatsinks)
|
|
|
|
|
|
*Kontron KISS 6U industrial PC**
|
|
|
|
|
|
<table>
|
|
|
<tbody>
|
|
|
<tr class="odd">
|
|
|
<td><strong>Slot</strong></td>
|
|
|
<td>1</td>
|
|
|
<td>2</td>
|
|
|
<td>3</td>
|
|
|
<td>7</td>
|
|
|
<td>8</td>
|
|
|
</tr>
|
|
|
<tr class="even">
|
|
|
<td><strong>Temperature</strong></td>
|
|
|
<td>88.19</td>
|
|
|
<td>81.94</td>
|
|
|
<td><span class="red">89.12</span></td>
|
|
|
<td>83.0</td>
|
|
|
<td><span class="blue">71.75</span></td>
|
|
|
</tr>
|
|
|
</tbody>
|
|
|
</table>
|
|
|
|
|
|
### Summary
|
|
|
|
|
|
<table>
|
... | ... | |