Federico Vaga authored
The calibration and the default range were not set consistently. The calibration initialization was running before when the default range was the result of a memset (0 -> 10V). The code that initialize the voltage range to 1V happens after but without applying again the calibration values. To solve the problem, now the function that sets the voltage range also sets the calibration values. Ding this allowed to reduce the code in the voltage range assignment in the ZIO part. Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
e6c895c4