    • Christos Gentsos's avatar
      PCB: implement comments from the design review (3/N) · 76420c29
      Christos Gentsos authored
      - replace IRFH5025PbF with IPD5N25S3-430 due to lower Vth shift
      - add test points in various places
      - add ceramic capacitors to MOSFETs and fans
      - add some labels/groups to indicated which connector is for what
      - reversed polarity of ESD protection on USB lines
      - add 32kHz crystal in parallel with 8MHz
      - add one more bypass cap to the uC
      - replace main connector part
      - show the power input/output voltage levels in the main sheet
      - the low side of temp. monitor connections is fixed to ground, make
        that more obvious
      76420c29
  14. 14 Feb, 2020 3 commits
  15. 28 Jan, 2020 2 commits
    • Christos Gentsos's avatar
      PCB: implement comments from the design review (2/N) · 624db4bb
      Christos Gentsos authored
      - connect "rst_n" line to "EN" input of IC2 to fully power-cycle uC
        instead of just resetting
      - remove 0.1% resistors
      - optimize resistor values
      - use just one type of 10UF capacitor
      - optimize capacitor values
      - use larger bypass caps for the MOSFETs
      - use a schottky instead of the ultrafast ES2A
      - add 10ohm current limiting resistors at the gate drivers
      - add a fast zener at the gates
      624db4bb
    • Christos Gentsos's avatar
      PCB: implement comments from the design review (1/N) · ba9b0eeb
      Christos Gentsos authored
      - CERN OHL: "Copyright 2019-2020"
      - 2.49k instead of 2.55k for the PT100 current drivers
      - to avoid copy&paste mistakes, a single temperature measurement
        channel could be placed in a separate sheet and just instantiated 3x
        in analog sheet
      - to avoid copy&paste mistakes, have 1 sheet with single fan channel
        and instantiate it multiple times even on the main sheet.
      ba9b0eeb