Commit b414abec authored by Adam Wujek's avatar Adam Wujek

pytest: add pytests for monimod

For main_fw and bootloader
Signed-off-by: 's avatarAdam Wujek <dev_public@wujek.eu>
parent 9ce110df
Pipeline #3772 passed with stage
in 46 seconds
"""
SPDX-License-Identifier: GPL-3.0-or-later
SPDX-FileCopyrightText: 2022 CERN
"""
import pytest
import subprocess
import time
import re
import os
import smbus
MONIMOD_ADDRESS = 0x12
MONIMOD_BUS = 0x9
MONIMOD_MFR_MODEL_BOOTLOADER = "DI/OT MoniMod (bl)"
MONIMOD_MFR_MODEL_MAIN = "DI/OT MoniMod"
MONIMOD_UPTIME_ADDR = 0xd7
MONIMOD_UPTIME_SIZE = 4
MONIMOD_TMR_ADDR = 0xd8
MONIMOD_TMR_SIZE = 4
class monimod:
FW_UNKNOWN = 0
FW_BOOTLOADER = 1
FW_MAIN = 2
cmd_ids = {
"PAGE" : 0x00,
"CAPABILITY" : 0x19,
"QUERY" : 0x1A,
"VOUT_MODE" : 0x20,
"FAN_CONFIG_1_2" : 0x3A,
"FAN_COMMAND_1" : 0x3B,
"FAN_COMMAND_2" : 0x3C,
"FAN_CONFIG_3_4" : 0x3D,
"FAN_COMMAND_3" : 0x3E,
"STATUS_BYTE" : 0x78,
"STATUS_CML" : 0x7E,
"READ_VOUT" : 0x8B,
"READ_IOUT" : 0x8C,
"READ_TEMPERATURE_1" : 0x8D,
"READ_TEMPERATURE_2" : 0x8E,
"READ_TEMPERATURE_3" : 0x8F,
"READ_FAN_SPEED_1" : 0x90,
"READ_FAN_SPEED_2" : 0x91,
"READ_FAN_SPEED_3" : 0x92,
"READ_POUT" : 0x96,
"MFR_ID" : 0x99,
"MFR_MODEL" : 0x9A,
"MFR_REVISION" : 0x9B,
"MFR_LOCATION" : 0x9C,
"MFR_DATE" : 0x9D,
"MFR_SERIAL" : 0x9E,
"IC_DEVICE_REV" : 0xAE,
# manufacturer specific commands
"WRITTEN_FW_SIZE" : 0xD1,
"WRITTEN_FW_BLOCK" : 0xD2,
"WRITTEN_FW_CHKSUM" : 0xD3,
"LOCAL_FW_CHKSUM" : 0xD4,
"BOOT_NEW_FW" : 0xD5,
"UC_RESET" : 0xD6,
"UPTIME_SECS" : 0xD7,
"TMR_ERROR_CNT" : 0xD8,
"USE_PEC" : 0xD9,
"TEMP_CURVE_POINTS" : 0xE0,
"TEMP_MATRIX_ROW" : 0xE1,
"TC_ONOFF" : 0xE2,
"DUMMY" : 0xfe,
"PMBUS_COMMAND_EXT" : 0xFF,
}
def __init__(self):
self.bus = smbus.SMBus(MONIMOD_BUS)
def var_to_str(self, var_as_ints):
return "".join([chr(x) for x in var_as_ints])
def pmbus_read_byte_cmd(self, cmd):
return self.bus.read_byte_data(MONIMOD_ADDRESS, cmd)
def pmbus_read_word_cmd(self, cmd):
return self.bus.read_word_data(MONIMOD_ADDRESS, cmd)
def pmbus_read_block_cmd(self, cmd):
return self.bus.read_block_data(MONIMOD_ADDRESS, cmd)
def read_i2c_block_data(self, cmd, read_size):
return self.bus.read_i2c_block_data(MONIMOD_ADDRESS, cmd, read_size)
def pmbus_block_process_call(self, cmd, vals):
return self.bus.block_process_call(MONIMOD_ADDRESS, cmd, vals)
def pmbus_write_byte_cmd(self, cmd, data):
return self.bus.write_byte_data(MONIMOD_ADDRESS, cmd, data)
def pmbus_write_word_cmd(self, cmd, data):
return self.bus.write_word_data(MONIMOD_ADDRESS, cmd, data)
def write_i2c_block_data(self, cmd, data):
return self.bus.write_i2c_block_data(MONIMOD_ADDRESS, cmd, data)
def get_fw_mode(self):
fw_model = self.pmbus_read_block_cmd(self.cmd_ids["MFR_MODEL"])
if self.var_to_str(fw_model) == MONIMOD_MFR_MODEL_BOOTLOADER:
return self.FW_BOOTLOADER
if self.var_to_str(fw_model) == MONIMOD_MFR_MODEL_MAIN:
return self.FW_MAIN
return self.FW_UNKNOWN
def switch_fw_mode(self):
return self.pmbus_write_byte_cmd(self.cmd_ids["BOOT_NEW_FW"], 1)
def set_page(self, page):
pass
def get_uptime(self):
data = self.read_i2c_block_data(self.cmd_ids["UPTIME_SECS"],
MONIMOD_UPTIME_SIZE)
return int.from_bytes(bytes(data), "little")
def get_tmr(self):
data = self.read_i2c_block_data(self.cmd_ids["TMR_ERROR_CNT"],
MONIMOD_TMR_SIZE)
return int.from_bytes(bytes(data), "little")
@pytest.fixture(scope="session")
def monimod_bus():
monimod_instance = monimod()
yield monimod_instance
def pytest_addoption(parser):
pass
def pytest_configure(config):
pass
# SPDX-License-Identifier: GPL-3.0-or-later
# SPDX-FileCopyrightText: 2020 CERN
[pytest]
addopts = -v -p no:cacheprovider
"""
SPDX-License-Identifier: GPL-3.0-or-later
SPDX-FileCopyrightText: 2022 CERN
"""
import pytest
import random
import smbus
import time
import warnings
QUERY_SUP = 0x80
QUERY_WR = 0x40
QUERY_RD = 0x20
QUERY_FMT_LIN = 0x00
QUERY_FMT_16B = 0x04
QUERY_FMT_DIR = 0x0c
QUERY_FMT_8B = 0x10
QUERY_FMT_VID = 0x14
QUERY_FMT_MAN = 0x18
QUERY_FMT_NAN = 0x1c
cmd_query = {
"PAGE" : QUERY_SUP | QUERY_WR | QUERY_RD | QUERY_FMT_8B,
"CAPABILITY" : QUERY_SUP | QUERY_RD,
"QUERY" : QUERY_SUP | QUERY_WR,
"VOUT_MODE" : QUERY_SUP | QUERY_RD,
"FAN_CONFIG_1_2" : QUERY_SUP | QUERY_WR | QUERY_RD | QUERY_FMT_NAN,
"FAN_COMMAND_1" : QUERY_SUP | QUERY_WR | QUERY_RD | QUERY_FMT_LIN,
"FAN_COMMAND_2" : QUERY_SUP | QUERY_WR | QUERY_RD | QUERY_FMT_LIN,
"FAN_CONFIG_3_4" : QUERY_SUP | QUERY_WR | QUERY_RD | QUERY_FMT_NAN,
"FAN_COMMAND_3" : QUERY_SUP | QUERY_WR | QUERY_RD | QUERY_FMT_LIN,
"STATUS_BYTE" : QUERY_SUP | QUERY_RD,
"STATUS_CML" : QUERY_SUP | QUERY_WR | QUERY_RD,
"READ_VOUT" : QUERY_SUP | QUERY_RD | QUERY_FMT_LIN,
"READ_IOUT" : QUERY_SUP | QUERY_RD | QUERY_FMT_LIN,
"READ_TEMPERATURE_1" : QUERY_SUP | QUERY_RD | QUERY_FMT_LIN,
"READ_TEMPERATURE_2" : QUERY_SUP | QUERY_RD | QUERY_FMT_LIN,
"READ_TEMPERATURE_3" : QUERY_SUP | QUERY_RD | QUERY_FMT_LIN,
"READ_FAN_SPEED_1" : QUERY_SUP | QUERY_RD | QUERY_FMT_LIN,
"READ_FAN_SPEED_2" : QUERY_SUP | QUERY_RD | QUERY_FMT_LIN,
"READ_FAN_SPEED_3" : QUERY_SUP | QUERY_RD | QUERY_FMT_LIN,
"READ_POUT" : QUERY_SUP | QUERY_RD | QUERY_FMT_LIN,
"MFR_ID" : QUERY_SUP | QUERY_RD | QUERY_FMT_NAN,
"MFR_MODEL" : QUERY_SUP | QUERY_RD | QUERY_FMT_NAN,
"MFR_REVISION" : QUERY_SUP | QUERY_RD | QUERY_FMT_NAN,
"MFR_LOCATION" : QUERY_SUP | QUERY_RD | QUERY_FMT_NAN,
"MFR_DATE" : QUERY_SUP | QUERY_RD | QUERY_FMT_NAN,
"MFR_SERIAL" : QUERY_SUP | QUERY_RD | QUERY_FMT_NAN,
"IC_DEVICE_REV" : QUERY_SUP | QUERY_RD | QUERY_FMT_NAN,
# manufacturer specific commands
"WRITTEN_FW_SIZE" : QUERY_SUP | QUERY_WR | QUERY_RD,
"WRITTEN_FW_BLOCK" : QUERY_SUP | QUERY_WR | QUERY_RD,
"WRITTEN_FW_CHKSUM" : QUERY_SUP | QUERY_WR | QUERY_RD,
"LOCAL_FW_CHKSUM" : QUERY_SUP | QUERY_RD,
"BOOT_NEW_FW" : QUERY_SUP | QUERY_WR | QUERY_RD,
"UC_RESET" : QUERY_SUP | QUERY_WR,
"UPTIME_SECS" : QUERY_SUP | QUERY_RD,
"TMR_ERROR_CNT" : QUERY_SUP | QUERY_WR | QUERY_RD,
"USE_PEC" : QUERY_SUP | QUERY_WR | QUERY_RD,
"TEMP_CURVE_POINTS" : QUERY_SUP | QUERY_WR | QUERY_RD,
"TEMP_MATRIX_ROW" : QUERY_SUP | QUERY_WR | QUERY_RD,
"TC_ONOFF" : QUERY_SUP | QUERY_WR | QUERY_RD,
}
MFR_ID = "CERN (BE/CEM)"
MFR_MODEL = "DI/OT MoniMod (bl)"
@pytest.fixture(scope="module", autouse=True)
def check_boot_mode(monimod_bus):
restore_boot_mode = 0
if monimod_bus.get_fw_mode() != monimod_bus.FW_BOOTLOADER:
restore_boot_mode = 1
monimod_bus.switch_fw_mode()
time.sleep(1)
if monimod_bus.get_fw_mode() != monimod_bus.FW_BOOTLOADER:
pytest.skip("Monimod not in bootloader mode! Unable to switch to bootloader!")
yield
if restore_boot_mode == 1:
monimod_bus.switch_fw_mode()
time.sleep(1)
if monimod_bus.get_fw_mode() != monimod_bus.FW_MAIN:
warnings.warn(UserWarning("Monimod not in main mode! Unable to switch to main mode."))
class TestBootloaderRegAccess(object):
@pytest.mark.check_uptime
@pytest.mark.parametrize("cmds", ["BOOT_NEW_FW",
"UC_RESET",
]
)
def test_byte_read(self, monimod_bus, cmds):
monimod_bus.pmbus_read_byte_cmd(monimod_bus.cmd_ids[cmds])
@pytest.mark.parametrize("cmds", ["WRITTEN_FW_SIZE" ,
"WRITTEN_FW_CHKSUM",
"LOCAL_FW_CHKSUM" ,
]
)
def test_word_read(self, monimod_bus, cmds):
monimod_bus.pmbus_read_word_cmd(monimod_bus.cmd_ids[cmds])
@pytest.mark.parametrize("cmds", ["MFR_ID",
"MFR_MODEL",
"MFR_REVISION",
"MFR_LOCATION",
"MFR_DATE",
"MFR_SERIAL",
"IC_DEVICE_REV"
]
)
def test_block_read(self, monimod_bus, cmds):
monimod_bus.pmbus_read_block_cmd(monimod_bus.cmd_ids[cmds])
@pytest.mark.parametrize("cmds", ["MFR_ID" ,
"MFR_MODEL" ,
"MFR_REVISION" ,
"MFR_LOCATION" ,
"MFR_DATE" ,
"MFR_SERIAL" ,
"IC_DEVICE_REV" ,
]
)
def test_write_fail(self, monimod_bus, cmds):
try:
monimod_bus.pmbus_write_byte_cmd(monimod_bus.cmd_ids[cmds], 0xFa)
except OSError:
return
pytest.fail("{:s} register should be read only! Is read-write.".format(cmds))
@pytest.mark.parametrize("cmds", ["QUERY" ,
"MFR_ID" ,
"MFR_MODEL" ,
"MFR_REVISION" ,
"MFR_LOCATION" ,
"MFR_DATE" ,
"MFR_SERIAL" ,
"IC_DEVICE_REV" ,
"WRITTEN_FW_SIZE" ,
"WRITTEN_FW_CHKSUM" ,
"LOCAL_FW_CHKSUM" ,
"BOOT_NEW_FW" ,
"UC_RESET" ,
]
)
def test_query(self, monimod_bus, cmds):
ret = monimod_bus.pmbus_block_process_call(monimod_bus.cmd_ids["QUERY"], [monimod_bus.cmd_ids[cmds]])
assert cmd_query[cmds] == ret[0], ("Read 0x{:X}, expected 0x{:X}".format(ret[0], cmd_query[cmds]))
class TestBootloaderRegValues(object):
def test_mfr_id(self, monimod_bus):
fw_id = monimod_bus.pmbus_read_block_cmd(monimod_bus.cmd_ids["MFR_ID"])
assert monimod_bus.var_to_str(fw_id) == MFR_ID
def test_mfr_model(self, monimod_bus):
fw_model = monimod_bus.pmbus_read_block_cmd(monimod_bus.cmd_ids["MFR_MODEL"])
assert monimod_bus.var_to_str(fw_model) == MFR_MODEL
@pytest.mark.check_uptime
class TestBootloaderOther(object):
def test_switch_to_bootloader(self, monimod_bus):
assert monimod_bus.get_fw_mode() == monimod_bus.FW_BOOTLOADER, "Monimod not in bootloader mode!"
monimod_bus.switch_fw_mode()
time.sleep(2)
assert monimod_bus.get_fw_mode() == monimod_bus.FW_MAIN, "Failed to switch to main mode!"
monimod_bus.switch_fw_mode()
time.sleep(2)
assert monimod_bus.get_fw_mode() == monimod_bus.FW_BOOTLOADER, "Failed to switch to bootloader mode!"
This diff is collapsed.