# ConfCall 23 Mar 2020
|
|
|
### Main Backplane
|
|
|
Here is the back side of the main backplane, where you can see the silkscreen on the power bags.
|
|
|
It's a pitty that in the 3D models there is no silkscreen, but for the moment let's continue like this.
|
|
|
Please use this picture also for the documentation, if needed.
|
|
|
![image](uploads/896f0e0d314f3320894782bc8676bee8/image.png)
|
|
|
|
|
|
### Crate Front Panel
|
|
|
There are 4 screw terminals; below you may see the connections to each one of them, so as to arrange best placement:
|
|
|
|
|
|
![image](uploads/1d521ec7249940040799e4d2ab8c7616/image.png)
|
|
|
![image](uploads/3c72b7adc4cf405181fc9b2b21784adb/image.png) <br>
|
|
|
![image](uploads/b6f9c3014a7058e5879fa9e67cfc517e/image.png)
|
|
|
![image](uploads/ee336366086f2a44979384078ec0c34a/image.png)
|
|
|
|
|
|
### Materials
|
|
|
We move forward with PVC cables; Eva to clarify
|
|
|
|
|
|
# WhatsApp exchange of 19 Mar 2020
|
|
|
|
|
|
1. Both Schroff and Elma PSUs fit well <br>
|
... | ... | @@ -401,4 +419,5 @@ RTM pcb dimensions are 100 x 100 mm |
|
|
Indeed this point is not clear in our specs. The monitoring component is mounted on the PSU and then it is accessed through the Utility connectors of the PSUs. There is no monitoring mounted on the backplane. For you, for the crate design, there is no extra cabling regarding the monitoring module; all the cabling of the crate is shown in Figure 11.
|
|
|
Ok
|
|
|
|
|
|
- Conductive coloring |
|
|
\ No newline at end of file |
|
|
- Conductive coloring
|
|
|
|