Commit ad232fa8 authored by Denia Bouhired-Ferrag's avatar Denia Bouhired-Ferrag

updated hardware review document

parent f0350618
...@@ -56,3 +56,13 @@ At B9 (bottom right). Missing silkscreen ‘Gnd’? ...@@ -56,3 +56,13 @@ At B9 (bottom right). Missing silkscreen ‘Gnd’?
PTS PTS
Is the PTS extended for checking the PCB revision number (correct assembly of components)? Is the PTS extended for checking the PCB revision number (correct assembly of components)?
---------------------------
Additional comments from the meeting:
Change fuse value on 12V rail. Increase up to 3 Amps.
GF_EN is actually GF_EN_N, must be updated in sheet 7, sheet 4 and sheet1.
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!