... | ... | @@ -16,8 +16,41 @@ blocking outputs/crate, that can be supported by the design. |
|
|
|
|
|
## Measurement procedure:
|
|
|
|
|
|
A conv-ttl-board is plugged on an ELMA crate with an RTM board.
|
|
|
|
|
|
A worst case 2MHZ pulse is fed to the board (Board running with gateware
|
|
|
v4 release)
|
|
|
- A conv-ttl-board is installed on an ELMA crate with an RTM board.
|
|
|
|
|
|
<!-- end list -->
|
|
|
|
|
|
- A worst case 2MHz pulse is fed to the board (Board running with
|
|
|
gateware v4 release).
|
|
|
- The SysMon on the ELMA crate allows access to current sensor data
|
|
|
from a telnet prompt.
|
|
|
- Note that the v4 fuse that is available on the 12V supply is shorted
|
|
|
to enable higher current consumption at the same time leaving the
|
|
|
crate in charge of shutting the +12V supply when the 5.5A crate
|
|
|
limit is reached.
|
|
|
- The number of channels running is gradually inctremented and current
|
|
|
consumption from the crate is recorded for number of channels.
|
|
|
|
|
|
<table>
|
|
|
<tbody>
|
|
|
<tr class="odd">
|
|
|
<td><b> Number of channels </b></td>
|
|
|
<td>1</td>
|
|
|
<td>2</td>
|
|
|
<td>3</td>
|
|
|
<td>4</td>
|
|
|
<td>5</td>
|
|
|
<td>6</td>
|
|
|
</tr>
|
|
|
<tr class="even">
|
|
|
<td><b> Current (A) </b></td>
|
|
|
<td></td>
|
|
|
<td></td>
|
|
|
<td></td>
|
|
|
<td></td>
|
|
|
<td></td>
|
|
|
<td></td>
|
|
|
</tr>
|
|
|
</tbody>
|
|
|
</table>
|
|
|
|