... | ... | @@ -5,9 +5,9 @@ This page contains information on a previous versions of the switch card. |
|
|
- capacitor **C176** should be not mounted by default (if it is mounted one can not program the chip with ISP)
|
|
|
- transistor **T7** has drain interchanged with source. Quick fix: mount upside down and rotated, as presented below.
|
|
|
|
|
|
![t7](https://gitlab.cern.ch/skulis/HGCSensorProbeCard/raw/master/hw/documentation/bugs/t7.jpg)
|
|
|
![t7](https://ohwr.org/project/array/array/raw/master/doc/img/misc/t7.jpg)
|
|
|
|
|
|
- pull up resistors are missing on DOUT of all ADG1414 ICs (IC90 - IC153).
|
|
|
* Quick fix: add 33kOhm resistor between pins 22 and 23.
|
|
|
* In case of PCB redesign: add 33kOhm between pin 22 and +3.3V
|
|
|
- resistor **R579** should be not mounted |
|
|
- resistor **R579** should be not mounted |
|
|