... | ... | @@ -162,6 +162,19 @@ Also, after roughly 6.5V a battery seems quickly to go to 0V. Until 6.7V we can |
|
|
sticker. Or possibly not even needed as no UV will read as 000
|
|
|
anyway.
|
|
|
|
|
|
---
|
|
|
|
|
|
## Compliance testing
|
|
|
|
|
|
* [Academy of EMC](https://www.academyofemc.com/emc-standards)
|
|
|
* Gives a good summary of the EMC standards
|
|
|
|
|
|
* The meter needs to comply with general standards IEC 61000-6-3 and IEC 61000-6-2 which mandate for a battery-powered device:
|
|
|
* CISPR32 (Radiated emissions)
|
|
|
* IEC 61000-4-2 (ESD immunity)
|
|
|
* IEC 61000-4-2 (Electromagnetic field immunity 80 MHz – 2.7 GHz)
|
|
|
* IEC 61000-4-8 (Magnetic field immunity at 50/60 Hz)
|
|
|
|
|
|
-----
|
|
|
|
|
|
Erik van der Bij - 23 September 2019 |
|
|
Erik van der Bij - 10 October 2019 |