... | ... | @@ -4,36 +4,65 @@ Power supply unit for emergency lamps that may need to be used in areas |
|
|
with radiation. The power supply consists of a transformer, a diode
|
|
|
bridge, capacitors and an optional voltage stabilisation device. It
|
|
|
converts a 207V to 253V 50Hz AC to a stable DC voltage and current, as
|
|
|
required by the LED load.
|
|
|
|
|
|
*TEMPLATE TEXT BELOW. PLEASE
|
|
|
MODIFY**
|
|
|
required by the LED
|
|
|
load.
|
|
|
|
|
|
![](/uploads/d8e4de2a1cbaa74242c7fb12729d1afe/smallpsuinbox.jpg)
|
|
|
|
|
|
## Functional specifications
|
|
|
|
|
|
## Block diagram
|
|
|
Technical Requirements:
|
|
|
Input Voltage: 230V AC RMS
|
|
|
Voltage Tolerance: +/-10%
|
|
|
Input Frequency: 50Hz
|
|
|
Frequency Tolerance: +/- 0.5Hz
|
|
|
Maximum power: 7W (measured at input terminals)
|
|
|
Voltage Output: As LED requirements
|
|
|
Current Output: As LED requirements
|
|
|
Earthing Regime: IT
|
|
|
Relevant standards to be observed: IEC 61000-3-2, EN 55015, EN 50082-1,
|
|
|
EN 50082-2
|
|
|
Whilst the standard conditions of the electrical network dictate 230V AC
|
|
|
with a margin of +/-10, due to cabling constraints within radiation
|
|
|
exposed areas it would be considered advantageous should the supply
|
|
|
continue to operate below the -10 threshold. Please note that compliance
|
|
|
with the standards requires the power supply to be installed within a
|
|
|
suitable enclosure, it is assumed this will be the responsibility of
|
|
|
those manufacturing the power supply and integrating it within their
|
|
|
existing products.
|
|
|
|
|
|
The power supply shall consist of a transformer, a diode bridge,
|
|
|
capacitor(s) and optional voltage stabilisation device. It shall convert
|
|
|
50Hz AC voltages from 207V RMS to 253V RMS to a stable DC voltage, as
|
|
|
required by the LED load. The power supply shall be designed to supply
|
|
|
the current requirements of the connected LED
|
|
|
load.
|
|
|
|
|
|
## Block diagram
|
|
|
![](/uploads/403ba0af326e31369466680d4334c34c/blockdiagpsu.jpg)
|
|
|
|
|
|
-----
|
|
|
|
|
|
## Project information
|
|
|
|
|
|
- [Software](Software)
|
|
|
- [Frequently Asked Questions](FAQ)
|
|
|
- [Frequently Asked
|
|
|
Questions](FAQ)
|
|
|
- [Users](Users)
|
|
|
|
|
|
-----
|
|
|
|
|
|
## Contacts
|
|
|
|
|
|
### Commercial producers
|
|
|
### Commercial producers
|
|
|
Luminaires based on earlier versions of this design (using the same principles) are currerntly produced by the following companies:
|
|
|
Comatelec (FR) \[http://www.schreder.com/frc-fr/Pages/default.aspx\]
|
|
|
Thorlux (UK) \[http://www.thorlux.com/\]
|
|
|
|
|
|
### Project
|
|
|
### Project Development
|
|
|
|
|
|
- [James Devine](mailto:jdevine@cern.ch) - CERN - General question
|
|
|
about project
|
|
|
- Jean Marie Foray - CERN - Engineer
|
|
|
- Jean Marie Foray - CERN - Engineer 2(009-2014)
|
|
|
|
|
|
-----
|
|
|
|
... | ... | @@ -47,7 +76,19 @@ MODIFY** |
|
|
</tr>
|
|
|
<tr class="even">
|
|
|
<td>27-05-2011</td>
|
|
|
<td>...</td>
|
|
|
<td>Initial testing of commerical prototypes for LED emergency lighting in radiation environment</td>
|
|
|
</tr>
|
|
|
<tr class="odd">
|
|
|
<td>04-07-2011</td>
|
|
|
<td>Development of technical solution following test outcomes</td>
|
|
|
</tr>
|
|
|
<tr class="even">
|
|
|
<td>05-03-2012</td>
|
|
|
<td>Production and test of solutions based on design principles by Thorlux & Comatelec</td>
|
|
|
</tr>
|
|
|
<tr class="odd">
|
|
|
<td>05-03-2012</td>
|
|
|
<td>Production and test of solutions based on design principles by Thorlux & Comatelec</td>
|
|
|
</tr>
|
|
|
</tbody>
|
|
|