... | @@ -2,13 +2,19 @@ |
... | @@ -2,13 +2,19 @@ |
|
|
|
|
|
### Monitoring information exposed by DI/OT crate to the fieldbus
|
|
### Monitoring information exposed by DI/OT crate to the fieldbus
|
|
|
|
|
|
| field | size (Bytes) | comments |
|
|
| Field | Size (Bytes) | Comments |
|
|
| ------ | ------ | ------ |
|
|
| ------ | ------ | ------ |
|
|
| Restart counter | 1 | |
|
|
| Restart counter | 1 | |
|
|
| Peripheral Boards presence flags | 1 | 1 bit per slot |
|
|
| Peripheral Boards presence flags | 1 | 1 bit per slot |
|
|
| Peripheral Boards ID | 16 (8x2B) | 2B per board for rad-tol variant |
|
|
| Peripheral Boards ID | 16 (8x2B) | 2B per board for rad-tol variant |
|
|
| Temperatures (3?) | 3x ?? | |
|
|
| Temperatures (4) | 4 | One per PSU, system board, one ambient. reduce 2B representation in sysboard FW |
|
|
| Currents (2) | 2x ?? | |
|
|
| Voltages (2) | 4 (2x2B) | 12V and 5V, values from the 2 PSUs are filtered / averaged by the sysboard FW |
|
|
| Fan speeds (2) | 2x ?? | |
|
|
| Currents (4) | 8 (4x2B) | Get values from both PSUs to monitor current sharing |
|
|
|
|
| Fan speeds (3) | 3 | Optional fan tray. Reduce 2B representation in sysboard FW |
|
|
|
|
| PSU status | 1 | PSU presence, status and model (RaToPUS or COTS) information |
|
|
|
|
| Reserved | 2 | Reserved for future use |
|
|
|
|
| ------ | ------ | ------ |
|
|
|
|
| Total bytes | 40 | |
|
|
|
|
|
|
|
|
|
|
### Peripheral Boards identification procedure |
|
### Peripheral Boards identification procedure |
|
|
|
\ No newline at end of file |