# EMC tests of non-rad-tol DI/OT system
|
|
|
|
|
|
## Levels of EMC environment as per standard 61000-4-4:
|
|
|
Levels of EMC environment as per standard 61000-4-4:
|
|
|
* **level 1**: well protected environment (e.g. computer room)
|
|
|
* **level 2**: protected environment (e.g. control room of instustrial plants)
|
|
|
* **level 3**: (5kHz, 100kHz, 2kV to power lines, 1kV to signal ports): industrial environment, no surpression of bursts, poor separation of industrial circuits, poor separation of power and signal cables
|
|
|
* **level 4**: (4kV to powerlines, 2kV to signal lines): heavy industrial, power plants, rely rooms
|
|
|
|
|
|
*Possible test results*
|
|
|
Possible test results:
|
|
|
* **A** - good performance
|
|
|
* **B** - some interuption that disapears after stopping test - automatic recovery
|
|
|
* **C** - temp loss of function but requires intervention (need to reset)
|
... | ... | |