... | ... | @@ -41,6 +41,13 @@ It seems there are only red rails for RTMs, to be confirmed; ideally they should |
|
|
|
|
|
- It is probable to be **compatible with other manufacturers**, but it would be a different analysis for Creotech to check for that; CERN could ask directly ELMA/ATOS for their equivalent BOMs and 3D models
|
|
|
|
|
|
- Files delivered today by Creotech:
|
|
|
* With RTM: https://autode.sk/39MD3JS
|
|
|
* Without RTM:https://autode.sk/2QSAM7i
|
|
|
* STEP files: https://www.dropbox.com/s/efn6d8k36e34zd8/DIOT_Crate.rar?dl=0
|
|
|
|
|
|
|
|
|
|
|
|
**17 Dec 2019:**
|
|
|
|
|
|
* We need to protect user from being electrocuted by accidentally touching **230V cables going to the front panel**. You will evaluate 2 solutions: 1) enclosing front panel in a "metal box" where 230V cables enter through a hole in the back and other than this, it is covered from all sides; 2) 2 metal plates separating slot 9 and PSU slot from the front panel area.
|
... | ... | |