### ***This means that during planning and installations, it is important to not allocate any more than 12 blocking output ports per crate. As the board is fuse-protected, failing to respect this limit will not damage the board, but will cause a failure in blocking repetition and will necessitate human intervention to replace the damaged fuse.***
|
|
### (red) ***This means that during planning and installations, it is important to not allocate any more than 12 active blocking output ports *in total* per crate, regardless of the number of boards in the crate (1). As the board is fuse-protected, failing to respect this limit will not damage the board, but will cause a failure in blocking repetition and will necessitate human intervention to replace the damaged fuse.***
|
|
|
|
|
|
|
|
(1)Could range from 12 boards with one blocking output channel each to 1
|
|
|
|
board with only 12 channels active out of the 18 available
|
|
|
|
|
|
Denia Bouhired, 31 March 2017.
|
|