• Theodor-Adrian Stana's avatar
    hdl: Fixed a problem with the pulse counters · 5dcc4b58
    Theodor-Adrian Stana authored
    When the TTL selection switch is set for TTL-BAR signals, the pulse counters
    were starting from the value 1. This was because the input channel is
    first sent through a synchronizer FF chain, which was reset by the
    same reset signal as the rest of the logic.
    
    Due to the reset pulse inside the logic and the fact that when the TTL switch
    is set to TTL-BAR, a non-existing signal represents a high level, this
    high level was detected (due to the sync FF chain) only after the reset pulse.
    This resulted in a rising edge on the trigger signal, which resulted in the
    pulse counters incrementing to '1' on every reset.
    
    This problem has been solved by not resetting the sync FF chain.
    Signed-off-by: Theodor-Adrian Stana's avatarTheodor Stana <t.stana@cern.ch>