Front Panel - too small opening for the fiber connector
The fiber connector does not fit into the hole in the front panel.
- the connector: 9.37 x 51.03 mm
- the hole in the design files: 9.4 x 51.1 mm
- the hole in the manufactured front panel: 9.35 x 51.04 mm
It seems that too little space was foreseen for the manufacturing tolerance. The hole was extended manually and things work well when the front panel hole is: 9.8 x 51.8 mm
The design files should be updated to state the size of the hole to be 9.8 x 51.8 mm