Commit 080d36d0 authored by Maciej Lipinski's avatar Maciej Lipinski Committed by Grzegorz Daniluk

[phytool] fix t24p measurement

softPLL was set in BC mode and current_reference changed during
the measurment. The problemw as that the before-measurement
setting was not recovered. This caused problems, in particular
during LPDC rx calibration of other ports.
parent 0a40af18
......@@ -1610,11 +1610,18 @@ int cal_ep_timestamper_cal_pulse()
/* legacy function for 'calibration force' command */
int measure_t24p(int endpoint, uint32_t *value)
{
int rv;
int rv, initial_mode, initial_current_ref;
printf("Measuring t24p for endpoint %d\n", endpoint );
rxts_calibration_init( endpoint );
/* read/remember mode/reference before the measurment,
to be restored at the end */
rts_get_state(&cal_pstate);
initial_mode = cal_pstate.mode;
initial_current_ref = cal_pstate.current_ref;
printf("Waiting for link...\n");
while(! (pcs_read(cal_endpoint, MII_BMSR) & BMSR_LSTATUS))
......@@ -1639,6 +1646,18 @@ int measure_t24p(int endpoint, uint32_t *value)
rxts_calibration_start();
while (!(rv = rxts_calibration_update(value))) ;
/* Go back to old settings of reference while still in BC mode */
rts_lock_channel( initial_current_ref, 0 );
/* Go back to the previous mode of PLL, only if it's not BC mode
NOTE: the rts_set_mode() function initializes softPLL to
DISABLED mode if it is called with RTS_MODE_BC argument), it
needs to be followed by rts_lock_channel() function which
initializes spll with SLAVE mode... */
if (initial_mode != RTS_MODE_BC)
rts_set_mode( initial_mode );
return rv;
}
......
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!