• Jean-Claude BAU's avatar
    HAL: Synchronize ports for RX calibration · eec4846d
    Jean-Claude BAU authored
    A minimum delay of 20s is applied to all port for the the RX
    calibration. After a reboot, all ports will be UP at the same time if
    the RX  calibration time is less than 20s.
    The same mechanism is applied all the time the link is going up.