EDA04509-V1-0 - Schematic sheet 8 'Trigger and Serial Mezzanine board'
-
The connector J6 is missing the 'Socket 12' value.
-
The comment
The Trigger and RS232 circuits should be placed on a mezzanine PCB mechanically connected to the inside of the front panel. This can for example be done using two Ettinger 05.60.422 or 05.60.125 mounting brackets mounted on the two plated 2.7mm mounting holes.
is related to the mezzanine board and doesn't apply to EDA04509-V1-0, so can be removed.
- The comment
This mezzanine PCB should be connected to the main PCB using the 'Header 12' and 'Socket 12'. The connector pin layout should be changed for better routing.
should be changed to
The mezzanine PCB should be connected to the main PCB using 'Socket 12'.
- The copyright box in the lower left corner shows a different layout compared to all other schematic pages where the copyright is presented as one line above the reference box.