V3-0 - Replace R6/R7 by 10 Ohm
- Replace R6 by recommended value of 10Ω.
Discussion:
Clock_generator.SchDoc:
- JGR: Why R6 and R7 are 100Ω? The recommended value is 10Ω
- NV: Can be 10Ω, yes. This is just a BOM and schematic change. The schematic section in the EDMS project is still “in work”, but the BOM is “released…
- EB: R6: TDC_REF_CLK: on Fine Delay module there is no series termination resistor for this signal. Replace R6 by recommended value of 10Ω.