Ethernet connectors' connection to the carrier front panel for EMC
Assess the possibility to use ethernet connectors with finger contacts for a good connection. Note the restricted space. If not possible ensure good connection elsewise, e.g. using electromagnetic gaskets. Keep the path connector->finger contacts->front panel->chassis as short as possible.