- 05 Jul, 2021 18 commits
-
-
Federico Vaga authored
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
5.0.3 - 2021-07-05 ================== Added: ----- - bld: CI support Fixed ----- - doc: add offset units - sw: calibration value at boot time incorrect - sw: use YAML for fau-calibration
-
Federico Vaga authored
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
It may help other programs to process this output Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
- 02 Jul, 2021 12 commits
-
-
Federico Vaga authored
The calibration and the default range were not set consistently. The calibration initialization was running before when the default range was the result of a memset (0 -> 10V). The code that initialize the voltage range to 1V happens after but without applying again the calibration values. To solve the problem, now the function that sets the voltage range also sets the calibration values. Ding this allowed to reduce the code in the voltage range assignment in the ZIO part. Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
Use containers, and more building tests. Remove the koji and RPM part (we will work on that again in the future but now it does not work anymore) Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
5.0.2 - 2021-07-03 ================== Fixed ----- - sw: calibration value for ADC were not applied correctly
-
Federico Vaga authored
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
The ADC calibration was applying DAC values Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
- 11 Jun, 2021 4 commits
-
-
Federico Vaga authored
5.0.0 - 2021-06-11 ================== Fixed ----- - sw: concurrent DMA transfers are possible thanks to a wait and retry algorithm - sw: wait 400ms before reading the temperature the first time (the hardware takes time to setup the thermometers) - doc: use cheby files from hdl instead of special implementations
-
Federico Vaga authored
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Federico Vaga authored
On SVEC we can have up to two FMC-ADC-100M mezzanine, potentially triggering at the same time. If such conditions, the driver fails in performing the DMA on both mezzanine because one of the two will fail to request a channel. With this patch we introducte a 10s timeout for the ADC to request a DMA channel on SVEC. Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
- 19 May, 2021 2 commits
-
-
Tristan Gingold authored
-
Tristan Gingold authored
-
- 11 May, 2021 2 commits
-
-
Federico Vaga authored
Signed-off-by: Federico Vaga <federico.vaga@cern.ch>
-
Tristan Gingold authored
-
- 12 Feb, 2021 2 commits
-
-
Federico Vaga authored
5.0.0 - 2021-02-11 ================== Changes ------- - channel sysfs attribute 'chx-offset' does not accept mV (milli-volts) values anymore. Now the unit is uV (micro-Volts) - acquisition sysfs attribute 'decimation' is now named 'undersample' - software trigger is enable by default - on DAC offset saturation set the maximum/minimum value instead of error - the software trigger is not anymore a ZIO attribute. It is now in debugfs Added ----- - multiple trigger sources at the same time - trigger threshold per-channel - channel sysfs attributes to set trigger threshold - sysfs binary attribute to overwrite run-time calibration data - add tool to get/set run-time calibration data - periodically update gain calibration for DAC and ADC - trigger time - MBLT support for SVEC Removed ------- - library is not supported anymore, use adc-lib (https://www.ohwr.org/projects/adc-lib) - fald-acq tool is not supported anymore, use adc-acq from adc-lib (https://www.ohwr.org/projects/adc-lib)
-
Federico Vaga authored
-