V6-0 - Create V6-1 EDMS files with capacitor changes and L8 removed.
I wrote to the Design office on 14/6/22:
We found some problems on our FMC-ADC100M cards, the EDA-02063-V6-0. https://edms.cern.ch/nav/EDA-02063-V6-0
It will require changes of some of the components (16 capacitors, one inductor), without changing the PCB. The required changes are described at https://ohwr.org/project/fmc-adc-100m14b4cha-hw/wikis/v6_0_to_v6_1
We should document those changes so that the latest schematics are correct. Although the problem is also present in earlier PCB versions, I think it is sufficient to make a V6-1 only.
Can you update V6-0 into a V6-1, or do you have other ways to treat cases like this?
Reply:
I just created the work order for this design change. I confirm it will be V6-1. If you list the old versions having the same problem, I will create a non-conformity dedicated for each version/execution. We will then know in case of new request for the old versions that we have to make design change before production.