- power-supply-1: P1V8AUX_PG connected to wrong IC30 channel
- SG-310 SCN is obsolete
- Add descriptions of sensors in schematics
- Wrong i2c address of MAX6639 on schematic
- DXP2 pin in MAX6639 not connected
- Update version resistors to reflect version v2.0
- Change license from CERN-OHL-S v2 to CERN-OHL-W v2
- Silkscreen modifications
- reorganise I2C bus
- add one more 24AA025E48-I/SN on I2C-WRFLASH bus
- Improve routing of FMC transceivers
- add a fuse on 12V before it goes to the FMC
- TVS diodes are placed after the series resistors
- WR-clocks: R55, R56, R60, R242, R243 should not be mounted to generate 62.5MHz WR helper clock
- fpga-config: SDIO_PROTECT and SDIO_DETECT should be pulled-up to P3V3 and NOT P1V8
- fpga-config: PS_MODE1/2 swapped at FPGA pins
- fpga-config: R160, R161, R162, R163 should be not mounted to allow for boot mode selection with SW1
- Replace C100 with higher voltage rating
- The reset pin of the flash chips is connected to ps_por_b which is 3.3V while the flash are 1.8V
- Missing pull-ups for PWRBTN_N and PWR_FAIL_N