[Crate Front Panel] Dimensions and Isolation Plate
Input from Ralf.Waldt@nVent.com
The dimension of the crate front panel pcb is 130 x 100 mm. It will be useful to increase the dimension to 160 x 100 mm because in this case a standard isolation plate can be used to avoid any safety issues. There is high voltage available on the solder side of the board and therefore this area should be protected.
The materials of the PCB cover are UL-listed. The test was however conducted with material thickness 1.5 mm.