Reading from ELMA crate used for checking (the one not power-cycled) Format in outputs if error: date and time / iteration number / slot number : [CH1 counter, CH2 counter, CH3 counter, CH4 counter, CH5 counter, CH6 counter] ------------------------------------------------------------ 2014-05-10-18h28m15s: starting test ------------------------------------------------------------ ERROR (2014-05-10-18h28m32s / iter 1 / slot 2) : [0, 0, 0, 0, 0, 1] ERROR (2014-05-10-18h28m49s / iter 2 / slot 2) : [0, 0, 1, 0, 0, 0] ERROR (2014-05-10-18h29m06s / iter 3 / slot 2) : [0, 0, 1, 0, 0, 0] ERROR (2014-05-10-18h29m24s / iter 4 / slot 2) : [0, 0, 0, 0, 0, 1] ------------------------------------------------------------ 2014-05-10-18h29m24s: ending test ------------------------------------------------------------ Number of iterations : 4 Number of errors (slot 1) : 0 Number of errors (slot 2) : 4